Printable version

Mar 25, 2015 How about using the MIB file from the 3PAR admin tools CD. Convert the MIB to a OIDLIB using Paesslers MIB converter. In PRTG, you will add an SNMP Library sensor and use the new OIDLIB file. 3par Mib Downloads Fresh House Flava 6 German Body Composition Program Charles Poliquin Supplements Depeche Mode Discography Mp3 Torrent Hollywood Cartoon Movies In Hindi Dubbed Hd For Pc Microsoft Sql Server 2005 Instance Wincc Tutorial Cisco Asdm 5.2 Download Free Vreveal Premium 3.1 Keygen 2016 - Free Download And Software.

  • The 3PAR MIB is contained within the 3PAR CLI download. The HP 3PAR SNMP agent supports SNMPv3, SNMPv2c, SMI-v2 standards. May 06, 2016 Advanced SNMP trap payload checking. An SNMP passive monitor that uses this definition will match all temperature traps generated by the Rackbotz device.
  • Wild Wild West 1999 Full Movie In Hindi Dubbed Download Ericsson Traffic Node Operation Manual Pdf File Compressor For Mac Ruby Mine Keygen Prototype 2.exe File Tamil Vishnusahasranamam Text Pdf Railworks 3 Train Simulator 2013 Tpb Awe 8525 Service Manual Cakewalk Home Studio 9 Crack 3par Mib Downloads.
  • Currently, there is no option to import custom MIBs that I am aware of within the product. 3PAR Incidents that are supported are more than one trap. It is a classification of traps called alertNotify. It is not the full set of traps for 3PAR, but it is more than one trap.

* RECOMMENDED * Agentless Management Service Offline Bundle for VMware ESXi 6.5

By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement.
Note: Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee.

Type:Software - System Management
Version:11.6.0(5 Oct 2020)
Operating System(s): VMware vSphere 6.5
File name:ams-esxi6.5-bundle-11.6.0-5.zip (12 MB)
The HPE Agentless Management Service (AMS) is a service that provides support for Agentless Management and Active Health. Agentless Management Service provides a wider range of server information (e.g. OS type and version, installed applications, IP addresses) allowing customers to complement hardware management with OS information and alerting. Agentless Management provides Integrated Lights Out (iLO) based robust management without the complexity of OS-based agents. Active Health provides 24x7 mission control for servers, delivering maximum uptime through automated monitoring, diagnostics and alerting. The contents of the HPE AMS offline bundle include the latest HPE Common Information Model (CIM) Limited Providers, HPE Integrated Lights Out (iLO) driver, HPE Compaq ROM Utility (CRU) driver, HPE Agentless Management Service (AMS) and Fibre Channel (FC) HBA access libraries. The Agentless Management Service (AMS) Offline Bundle only includes the Limited HPE CIM Providers which are not sufficient to support Online Driver and FW update using HPE Smart Update Manager (HPE SUM) and the HPE Service Pack for ProLiant (HPE SPP).

Agentless Management Service

  • Added the option to enable/disable AHS Logical Disk Usage logging

To ensure the integrity of your download, HPE recommends verifying your results with this SHA-256 Checksum value:

8190f82f4073ad7ab85db8d163d3989228a04787f660119e51805f553bb9e03bams-esxi6.5-bundle-11.6.0-5.zip

Reboot Requirement:
Reboot is required after installation for updates to take effect and hardware stability to be maintained.

Installation:

Installing Offline Bundles on an ESXi 6.5 Host Using ESXi CLI 6.5 esxcli Utility

You can use the esxcli utility in conjunction with offline bundles or with a depot. This topic describes the procedure using offline bundles.

Prerequisites
Before you can update or patch an ESXi 6.5 host from the command line, you must have access to a machine on which you can run the VMware ESXi Command-Line Interface 6.5 (ESXi CLI). You can install the ESXi CLI on your Microsoft Windows or Linux system. For information about importing or installing the ESXi CLI 6.5, see the VMware ESXi Command-Line Interface Guides.

Procedure

  1. Power off any virtual machines that are running on the host and place the host into maintenance mode.
  2. Transfer the offline bundle onto the ESXi host local path, or extract it onto an online depot.
  3. Install the bundle on the ESXi host.
    • Install remotely from client, with offline bundle contents on a online depot:
      esxcli -s <server> -u root -p mypassword software vib install -d <depotURL/bundle-index.xml>
    • Install remotely from client, with offline bundle on ESXi host:
      esxcli -s <server> -u root -p mypassword software vib install -d <ESXi local path><bundle.zip>
    • Install from ESXi host, with offline bundle on ESXi host:
      esxcli software vib install -d <ESXi local path><bundle.zip>
  4. After the bundle is installed, reboot the ESXi host for the updates to take effect.
  5. (Optional) Verify that the vibs on the bundle are installed on your ESXi host:
    esxcli -s <server> -u root -p mypassword software vib list
  6. (Optional) Remove individual vibs. <vib name> can be identified by listing the vibs as shown in #5:
    esxcli -s <server> -u root -p mypassword software vib remove -n <vib name>

Installing Offline Bundles on an ESXi 6.5 Host Using VMware vCenter Update Manager

The offline bundle can also be installed from VMware vCenter Update Manager as a patch. For more information and detailed instructions, see the VMware vCenter Update Manager Administration Guide.
Installing HPE ESXi 6.5 AMS Offline Bundle over HPE ESXi 6.5 Management Offline Bundle or vice-versa
If the HPE Custom ISO or the HPE Offline Management Bundle was installed, then no changes are required to use a solution based on Agentless Management vs the full HPE Insight management WBEM Providers and visa-versa.
The following procedure should be performed only if the HPE Custom ISO or the HPE Offline Management Bundle was installed and afterwards it is desirable to use a solution solely based on Agentless Management.
Procedure:

  1. Install the HPE ESXi 6.5 AMS Offline Bundle.

The following procedure should be performed only if the AMS bundle was installed and afterwards it is desirable to use a solution based on the full HPE Insight Management WBEM Providers.
Procedure:
1. Install the HPE ESXi 6.5 Management Offline Bundle, that includes the full HPE Insight Management WBEM Providers

End User License Agreements:
HPE Software License Agreement v1
Net-SNMP License
Hewlett-Packard End User License Agreement

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Supported Devices and Features:

VMware ESXi version support:

  • VMware ESXi 6.5 U2
  • VMware ESXi 6.5 U3

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Agentless Management Service

  • Add support for distributed switch to resolve AMS issue of not reporting the Host IP address
  • Fix duplicate IP address reporting issue
  • Add fix to skip CPU and Memory Usage data collection when CPU and Memory Usage Logging is disabled
  • Disable Logical Disk Usage logging by default
Version:11.6.0 (5 Oct 2020)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Agentless Management Service

  • Add support for distributed switch to resolve AMS issue of not reporting the Host IP address
  • Fix duplicate IP address reporting issue
  • Add fix to skip CPU and Memory Usage data collection when CPU and Memory Usage Logging is disabled
  • Disable Logical Disk Usage logging by default

Agentless Management Service

  • Added the option to enable/disable AHS Logical Disk Usage logging

Version:11.5.0 (17 Jan 2020)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

WBEM Providers

  • Fix incorrect CacheOperationalStatus data for Smart Array B140i Controller
  • Fix memory leak issues causing ESXi host to become unresponsive or crash

Agentless Management Service

  • Fix buffer overrun when acquiring vib summary from ESXi host database
  • Fix cpqSePciSlotBoardName for empty slots with no CPU
  • Fix cpqSePciSlotBoardName for FC Adapters with specific Device IDs
  • Disable multiple IPv6 support in Gen9 to fix Host discovery issues due to missing support in iLO
  • Fix AMS hang when total IPv6 address string sizes exceed 256 bytes

Version:11.4.5 (16 Sep 2019)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Agentless Management Service

  • Fixed issue with AMS filling up tmp and causing VUM updates to Fail (https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00073323en_us)
  • Fixed issue with read spikes seen in Gen9 hosts with HPE 3PAR only every 5 minutes

Agentless Management Service

  • Added support for HPE Ethernet 10Gb 2-port 524SFP+ Adapter and HPE Ethernet 10Gb 2-port 548SFP+ Adapter

Version:11.4.0 (12 Apr 2019)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

WBEM Providers

  • Fixed false Solid State Disk Wear alert reported by the SmartArray WBEM provider

Agentless Management Service

  • Fixed reporting of HPE QLogic NX2 driver components in the cpqHoSwVer MIB to resolve blank Installed driver versions displayed in SUM

Agentless Management Service

  • Added support for cpqiscsi MIB
  • Implement configurable CPU and Memory Usage periodic logging to the iLO AHS (Active Health System) Log

Version:11.3.6 (29 Nov 2018)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Agentless Management Service

  • Fixed reporting of HPE Software in the cpqHoSwVer MIB to resolve blank Active versions for installed drivers displayed in SUM.
  • Fixed AMS crash when processing a Link Down/Up Trap for a NIC port that has multiple IPV6 addresses.

Version:11.3.0 (27 Jun 2018)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Agentless Management Service

  • Fixed to remove heartbeat trap (cpqHo2GenericTrap) delivery at OS boot when periodic test trap feature is disabled
  • Fixed memory leak partly caused by AMS running in the OS init resource group
  • Fixed reporting of the embedded SATA controller to resolve missing drives in the iLO Storage Tab display

Agentless Management Service

  • Added reporting of OS Logical Disk Volume Configuration and Utilization to iLO's Active Health System Log

Version:11.2.0 (21 Mar 2018)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Pdf spanish conversation for beginners esl. Agentless Management Service

  • Fixed continuous PCIe Disk Temperature Failed (cpqSePCIeDiskTemperatureFailed) and PCIe Disk Wear Status Change (cpqSePCIeDiskWearStatusChange) traps when there are 3 or more NVMe drives in the system.

Agentless Management Service

  • Added reporting capability for the following information:
    • Part number for HPE Dual 8GB MicroSD EM USB Device
    • Multiple IPV6 addresses configured for Ethernet ports
  • Added support for the following features:
    • HPE Smart Array P824i-p MR controller
    • Periodic heartbeat trap (cpqHo2GenericTrap)
    • Host OS Graceful shutdown due to Critical Thermal/Fan Failure events in HPE Gen10 Servers

Version:11.1.5 (9 Nov 2017)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

HPE Insight Management WBEM Providers:

HPE Insight Management WBEM Providers does not report HPE Dynamic Smart Array B140i Controller Information if nhpsa driver supported Smart Array Controller is also configured in that server on vSphere 6.5

This issue is observed on vSphere 6.5 when the server is configured with an HPE Dynamic Smart Array B140i Controller supported by the hpdsa driver and smart array controller supported by the nhpsa driver. In this configuration, the HPE Insight Management WBEM Provider do not report the HPE Dynamic Smart Array B140i Controller instances information it only reports the Smart Array Controller instances information.

HPE Insight Management WBEM Providers does not support HPE Smart Array P816i-a SR Gen10 controller on vSphere 6.0 and 6.5

This issue is observed on both vSphere 6.0 and 6.5 OS, when the server is configured with HPE Smart Array P816i-a SR Gen10 controller. In this configuration, the HPE Insight Management WBEM Providers do not report any information of the HPE Smart Array P816i-a SR Gen10 controller.

HPE Insight Management WBEM Providers is not reporting the actual OperationalStatus of FC port and WBEM indications are also not generated

When FC Adapter “HP FlexFabric 10Gb 2-port 536FLB” is installed on a server and the FC cable is connected or disconnected from ports, HPE Insight Management WBEM Providers report wrong value for the OperationalStatus property in FC Provider classes and the WBEM indications are not generated. OperationalStatus reports the changed status only after WBEM Provider restarts.

Fixed memory leak. For more information, see the customer advisory at http://h20565.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-a00019892en_us.

Added HPE Insight Management WBEM Provider support for new FCHBA


Version:11.1.0 (12 Jul 2017)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

AMS fixes:

  • Fixed /tmp folder exhaustion with ahs.debug file when running over 128 CPU threads on the Host Server
  • Fixed AMS crash when multiple NICs of the same driver are installed

AMS features:

  • Added new SMA (System Management Assistant) feature for Gen10 which allows SNMP traps generated by iLO Agentless Management and AMS to be delivered through the Host OS Management Port
  • Added support for new MIB OIDs cpqSasPhyDrvSsBoxModel, cpqSasPhyDrvSsBoxSerialNumber, cpqSasPhyDrvSsBoxFwRev, and cpqSasPhyDrvSsBoxVendor

Agentless Management Service script to manually stop or restart AMS has changed (from hp-ams.sh) to ams.sh


Version:10.6.2 (15 May 2017)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

There is an updated hpe-ilo driver included in this bundle. For more information, see the VMware Knowledge Base Article at http://kb.vmware.com/kb/2148123and the HPE Customer Advisory at http://h20565.www2.hpe.com/hpsc/doc/public/display?docId=c05378386.


Version:10.6.0 (18 Nov 2016)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

AMS features:

  • Added support for new SNMP traps for HPE NVMe PCIe Solid State Drives

Type:Software - System Management
Version:11.6.0(5 Oct 2020)
Operating System(s):
VMware vSphere 6.5

Description

The HPE Agentless Management Service (AMS) is a service that provides support for Agentless Management and Active Health. Agentless Management Service provides a wider range of server information (e.g. OS type and version, installed applications, IP addresses) allowing customers to complement hardware management with OS information and alerting. Agentless Management provides Integrated Lights Out (iLO) based robust management without the complexity of OS-based agents. Active Health provides 24x7 mission control for servers, delivering maximum uptime through automated monitoring, diagnostics and alerting. The contents of the HPE AMS offline bundle include the latest HPE Common Information Model (CIM) Limited Providers, HPE Integrated Lights Out (iLO) driver, HPE Compaq ROM Utility (CRU) driver, HPE Agentless Management Service (AMS) and Fibre Channel (FC) HBA access libraries. The Agentless Management Service (AMS) Offline Bundle only includes the Limited HPE CIM Providers which are not sufficient to support Online Driver and FW update using HPE Smart Update Manager (HPE SUM) and the HPE Service Pack for ProLiant (HPE SPP).

Enhancements

Agentless Management Service

  • Added the option to enable/disable AHS Logical Disk Usage logging

Installation Instructions

To ensure the integrity of your download, HPE recommends verifying your results with this SHA-256 Checksum value:

8190f82f4073ad7ab85db8d163d3989228a04787f660119e51805f553bb9e03bams-esxi6.5-bundle-11.6.0-5.zip

Reboot Requirement:
Reboot is required after installation for updates to take effect and hardware stability to be maintained.

Installation:

Installing Offline Bundles on an ESXi 6.5 Host Using ESXi CLI 6.5 esxcli Utility

You can use the esxcli utility in conjunction with offline bundles or with a depot. This topic describes the procedure using offline bundles.

Prerequisites
Before you can update or patch an ESXi 6.5 host from the command line, you must have access to a machine on which you can run the VMware ESXi Command-Line Interface 6.5 (ESXi CLI). You can install the ESXi CLI on your Microsoft Windows or Linux system. For information about importing or installing the ESXi CLI 6.5, see the VMware ESXi Command-Line Interface Guides.

Procedure

  1. Power off any virtual machines that are running on the host and place the host into maintenance mode.
  2. Transfer the offline bundle onto the ESXi host local path, or extract it onto an online depot.
  3. Install the bundle on the ESXi host.
    • Install remotely from client, with offline bundle contents on a online depot:
      esxcli -s <server> -u root -p mypassword software vib install -d <depotURL/bundle-index.xml>
    • Install remotely from client, with offline bundle on ESXi host:
      esxcli -s <server> -u root -p mypassword software vib install -d <ESXi local path><bundle.zip>
    • Install from ESXi host, with offline bundle on ESXi host:
      esxcli software vib install -d <ESXi local path><bundle.zip>
  4. After the bundle is installed, reboot the ESXi host for the updates to take effect.
  5. (Optional) Verify that the vibs on the bundle are installed on your ESXi host:
    esxcli -s <server> -u root -p mypassword software vib list
  6. (Optional) Remove individual vibs. <vib name> can be identified by listing the vibs as shown in #5:
    esxcli -s <server> -u root -p mypassword software vib remove -n <vib name>

Installing Offline Bundles on an ESXi 6.5 Host Using VMware vCenter Update Manager

The offline bundle can also be installed from VMware vCenter Update Manager as a patch. For more information and detailed instructions, see the VMware vCenter Update Manager Administration Guide.
Installing HPE ESXi 6.5 AMS Offline Bundle over HPE ESXi 6.5 Management Offline Bundle or vice-versa
If the HPE Custom ISO or the HPE Offline Management Bundle was installed, then no changes are required to use a solution based on Agentless Management vs the full HPE Insight management WBEM Providers and visa-versa.
The following procedure should be performed only if the HPE Custom ISO or the HPE Offline Management Bundle was installed and afterwards it is desirable to use a solution solely based on Agentless Management.
Procedure:

  1. Install the HPE ESXi 6.5 AMS Offline Bundle.

The following procedure should be performed only if the AMS bundle was installed and afterwards it is desirable to use a solution based on the full HPE Insight Management WBEM Providers.
Procedure:
1. Install the HPE ESXi 6.5 Management Offline Bundle, that includes the full HPE Insight Management WBEM Providers

Release Notes

End User License Agreements:
HPE Software License Agreement v1
Net-SNMP License
Hewlett-Packard End User License Agreement

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Supported Devices and Features:

VMware ESXi version support:

  • VMware ESXi 6.5 U2
  • VMware ESXi 6.5 U3

Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Agentless Management Service

  • Add support for distributed switch to resolve AMS issue of not reporting the Host IP address
  • Fix duplicate IP address reporting issue
  • Add fix to skip CPU and Memory Usage data collection when CPU and Memory Usage Logging is disabled
  • Disable Logical Disk Usage logging by default

Revision History

Version:11.6.0 (5 Oct 2020)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Agentless Management Service

  • Add support for distributed switch to resolve AMS issue of not reporting the Host IP address
  • Fix duplicate IP address reporting issue
  • Add fix to skip CPU and Memory Usage data collection when CPU and Memory Usage Logging is disabled
  • Disable Logical Disk Usage logging by default

Agentless Management Service

  • Added the option to enable/disable AHS Logical Disk Usage logging

Version:11.5.0 (17 Jan 2020)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

WBEM Providers

  • Fix incorrect CacheOperationalStatus data for Smart Array B140i Controller
  • Fix memory leak issues causing ESXi host to become unresponsive or crash

Agentless Management Service

  • Fix buffer overrun when acquiring vib summary from ESXi host database
  • Fix cpqSePciSlotBoardName for empty slots with no CPU
  • Fix cpqSePciSlotBoardName for FC Adapters with specific Device IDs
  • Disable multiple IPv6 support in Gen9 to fix Host discovery issues due to missing support in iLO
  • Fix AMS hang when total IPv6 address string sizes exceed 256 bytes

Version:11.4.5 (16 Sep 2019)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Agentless Management Service

  • Fixed issue with AMS filling up tmp and causing VUM updates to Fail (https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00073323en_us)
  • Fixed issue with read spikes seen in Gen9 hosts with HPE 3PAR only every 5 minutes

Agentless Management Service

  • Added support for HPE Ethernet 10Gb 2-port 524SFP+ Adapter and HPE Ethernet 10Gb 2-port 548SFP+ Adapter

Version:11.4.0 (12 Apr 2019)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

WBEM Providers

  • Fixed false Solid State Disk Wear alert reported by the SmartArray WBEM provider

Agentless Management Service

  • Fixed reporting of HPE QLogic NX2 driver components in the cpqHoSwVer MIB to resolve blank Installed driver versions displayed in SUM

Agentless Management Service

  • Added support for cpqiscsi MIB
  • Implement configurable CPU and Memory Usage periodic logging to the iLO AHS (Active Health System) Log

Version:11.3.6 (29 Nov 2018)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Agentless Management Service

  • Fixed reporting of HPE Software in the cpqHoSwVer MIB to resolve blank Active versions for installed drivers displayed in SUM.
  • Fixed AMS crash when processing a Link Down/Up Trap for a NIC port that has multiple IPV6 addresses.

Version:11.3.0 (27 Jun 2018)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Agentless Management Service

  • Fixed to remove heartbeat trap (cpqHo2GenericTrap) delivery at OS boot when periodic test trap feature is disabled
  • Fixed memory leak partly caused by AMS running in the OS init resource group
  • Fixed reporting of the embedded SATA controller to resolve missing drives in the iLO Storage Tab display

Agentless Management Service

  • Added reporting of OS Logical Disk Volume Configuration and Utilization to iLO's Active Health System Log

Version:11.2.0 (21 Mar 2018)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Agentless Management Service

  • Fixed continuous PCIe Disk Temperature Failed (cpqSePCIeDiskTemperatureFailed) and PCIe Disk Wear Status Change (cpqSePCIeDiskWearStatusChange) traps when there are 3 or more NVMe drives in the system.

Agentless Management Service

  • Added reporting capability for the following information:
    • Part number for HPE Dual 8GB MicroSD EM USB Device
    • Multiple IPV6 addresses configured for Ethernet ports
  • Added support for the following features:
    • HPE Smart Array P824i-p MR controller
    • Periodic heartbeat trap (cpqHo2GenericTrap)
    • Host OS Graceful shutdown due to Critical Thermal/Fan Failure events in HPE Gen10 Servers

Version:11.1.5 (9 Nov 2017)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

HPE Insight Management WBEM Providers:

HPE Insight Management WBEM Providers does not report HPE Dynamic Smart Array B140i Controller Information if nhpsa driver supported Smart Array Controller is also configured in that server on vSphere 6.5

This issue is observed on vSphere 6.5 when the server is configured with an HPE Dynamic Smart Array B140i Controller supported by the hpdsa driver and smart array controller supported by the nhpsa driver. In this configuration, the HPE Insight Management WBEM Provider do not report the HPE Dynamic Smart Array B140i Controller instances information it only reports the Smart Array Controller instances information.

HPE Insight Management WBEM Providers does not support HPE Smart Array P816i-a SR Gen10 controller on vSphere 6.0 and 6.5

This issue is observed on both vSphere 6.0 and 6.5 OS, when the server is configured with HPE Smart Array P816i-a SR Gen10 controller. In this configuration, the HPE Insight Management WBEM Providers do not report any information of the HPE Smart Array P816i-a SR Gen10 controller.

HPE Insight Management WBEM Providers is not reporting the actual OperationalStatus of FC port and WBEM indications are also not generated

When FC Adapter “HP FlexFabric 10Gb 2-port 536FLB” is installed on a server and the FC cable is connected or disconnected from ports, HPE Insight Management WBEM Providers report wrong value for the OperationalStatus property in FC Provider classes and the WBEM indications are not generated. OperationalStatus reports the changed status only after WBEM Provider restarts.

Fixed memory leak. For more information, see the customer advisory at http://h20565.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-a00019892en_us.

Added HPE Insight Management WBEM Provider support for new FCHBA


Version:11.1.0 (12 Jul 2017)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

AMS fixes:

  • Fixed /tmp folder exhaustion with ahs.debug file when running over 128 CPU threads on the Host Server
  • Fixed AMS crash when multiple NICs of the same driver are installed

AMS features:

  • Added new SMA (System Management Assistant) feature for Gen10 which allows SNMP traps generated by iLO Agentless Management and AMS to be delivered through the Host OS Management Port
  • Added support for new MIB OIDs cpqSasPhyDrvSsBoxModel, cpqSasPhyDrvSsBoxSerialNumber, cpqSasPhyDrvSsBoxFwRev, and cpqSasPhyDrvSsBoxVendor

Agentless Management Service script to manually stop or restart AMS has changed (from hp-ams.sh) to ams.sh


Version:10.6.2 (15 May 2017)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

There is an updated hpe-ilo driver included in this bundle. For more information, see the VMware Knowledge Base Article at http://kb.vmware.com/kb/2148123and the HPE Customer Advisory at http://h20565.www2.hpe.com/hpsc/doc/public/display?docId=c05378386.


Version:10.6.0 (18 Nov 2016)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

AMS features:

  • Added support for new SNMP traps for HPE NVMe PCIe Solid State Drives

Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models.

3par Mib Downloads Free

Printable version
3par Mib Downloads

* RECOMMENDED * HPE Offline Bundle for ESXi 6.5

By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement.
Note: Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee.

Type:Software - System Management
Version:3.6.0(5 Oct 2020)
Operating System(s): VMware vSphere 6.5
File name:esxi6.5uX-mgmt-bundle-3.6.0-9.zip (15 MB)
The HPE ESXi Offline Bundle for VMware ESXi 6.5 includes the latest HPE Common Information Model (CIM) Providers, HPE Integrated Lights-Out (iLO) driver, HPE Compaq ROM Utility (CRU) driver, the HPE Agentless Management Service (AMS), and Fibre Channel(FC) HBA access libraries.

Agentless Management Service

Added the option to enable/disable AHS Logical Disk Usage logging

To ensure the integrity of your download, HPE recommends verifying your results with this SHA-256 Checksum value:

55bcdc680d52ad56d9428249eb6a702ba873ec94848ad096ea5712020ed3e54desxi6.5uX-mgmt-bundle-3.6.0-9.zip

Reboot Requirement:
Reboot is required after installation for updates to take effect and hardware stability to be maintained.

Installation:

Installing Offline Bundles on an vSphere 6.5 Host Using vSphere CLI 6.5 esxcli Utility

You can use the esxcli utility in conjunction with offline bundles or with a depot. This topic describes
the procedure using offline bundles.

Prerequisites
Before you can update or patch an vSphere 6.5 host from the command line, you must have access to a machine on which you can run the VMware vSphere Command-Line Interface 6.5 (vSphere CLI). You can install the vSphere CLI on your Microsoft Windows or Linux system. For information about importing or installing the
vSphere CLI 6.5, see the VMware vSphere Command-Line Interface Installation and Reference Guide.

Procedure

  1. Power off any virtual machines that are running on the host and place the host into maintenance mode.
  2. Transfer the offline bundle onto the ESXi host local path, or extract it onto an online depot.
  3. Install the bundle on the ESXi host.
    • Install remotely from client, with offline bundle contents on a online depot:
      esxcli -s <server> -u root -p mypassword software vib install -d <depotURL/bundle-index.xml>
    • Install remotely from client, with offline bundle on ESXi host:
      esxcli -s <server> -u root -p mypassword software vib install -d <ESXi local path><bundle.zip>
    • Install from ESXi host, with offline bundle on ESXi host:
      esxcli software vib install -d <ESXi local path><bundle.zip>
  4. After the bundle is installed, reboot the ESXi host for the updates to take effect.
  5. (Optional) Verify that the vibs on the bundle are installed on your ESXi host.
    esxcli -s <server> -u root -p mypassword software vib list
  6. (Optional) Remove individual vibs. <vib name> can be identified by listing the vibs as shown in #5.
    esxcli -s <server> -u root -p mypassword software vib remove -n <vib name>

Installing Offline Bundles on an vSphere 6.5 Host Using VMware vCenter Update Manager

The offline bundle can also be installed from VMware vCenter Update Manager as a patch. For more information and detailed instructions, see the VMware vCenter Update Manager Administration Guide.

End User License Agreements:
HPE Software License Agreement v1
Eclipse License
Libcurl End User License Agreement
Net-SNMP License
SNIA License
zlib End User License Agreement
Hewlett-Packard End User License Agreement

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Notes:

The HPE CIM Providers use modified SNIA HBAAPI open source code and is covered by the SNIA License.
A document of the changes made and the modified source code are available at http://vibsdepot.hpe.com/hpq/SNIA/HBAAPI/

Supported Devices and Features:

VMware vSphere version support:

  • VMware vSphere 6.5 U2
  • VMware vSphere 6.5 U3

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Agentless Management Service

  • Add support for distributed switch to resolve AMS issue of not reporting the Host IP address
  • Fix duplicate IP address reporting issue
  • Add fix to skip CPU and Memory Usage data collection when CPU and Memory Usage Logging is disabled
  • Disable Logical Disk Usage logging by default
Version:3.6.0 (5 Oct 2020)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Agentless Management Service

  • Add support for distributed switch to resolve AMS issue of not reporting the Host IP address
  • Fix duplicate IP address reporting issue
  • Add fix to skip CPU and Memory Usage data collection when CPU and Memory Usage Logging is disabled
  • Disable Logical Disk Usage logging by default

Agentless Management Service

Added the option to enable/disable AHS Logical Disk Usage logging


Version:3.5.0 (17 Jan 2020)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

WBEM Providers

  • Fix incorrect CacheOperationalStatus data for Smart Array B140i Controller
  • Fix memory leak issues causing ESXi host to become unresponsive or crash

Agentless Management Service

  • Fix buffer overrun when acquiring vib summary from ESXi host database
  • Fix cpqSePciSlotBoardName for empty slots with no CPU
  • Fix cpqSePciSlotBoardName for FC Adapters with specific Device IDs
  • Disable multiple IPv6 support in Gen9 to fix Host discovery issues due to missing support in iLO
  • Fix AMS hang when total IPv6 address string sizes exceed 256 bytes

Version:3.4.5 (16 Sep 2019)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Agentless Management Service

  • Fixed issue with AMS filling up tmp and causing VUM updates to Fail (https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00073323en_us)
  • Fixed issue with read spikes seen in Gen9 hosts with HPE 3PAR only every 5 minutes

Agentless Management Service

  • Added support for HPE Ethernet 10Gb 2-port 524SFP+ Adapter and HPE Ethernet 10Gb 2-port 548SFP+ Adapter

Version:3.4.0 (2 Apr 2019)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

WBEM Providers

  • Fixed false Solid State Disk Wear alert reported by the SmartArray WBEM provider

Agentless Management Service

  • Fixed reporting of HPE QLogic NX2 driver components in the cpqHoSwVer MIB to resolve blank Installed driver versions displayed in SUM

Agentless Management Service

  • Added support for cpqiscsi MIB
  • Implement configurable CPU and Memory Usage periodic logging to the iLO AHS (Active Health System) Log

Version:3.3.6 (29 Nov 2018)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Agentless Management Service

  • Fixed reporting of HPE Software in the cpqHoSwVer MIB to resolve blank Active versions for installed drivers displayed in SUM.
  • Fixed AMS crash when processing a Link Down/Up Trap for a NIC port that has multiple IPV6 addresses.

Version:3.3.0 (27 Jun 2018)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

WBEM Providers

  • Fixed issue with Smart Array Provider reporting change of battery status frequently

Agentless Management Service

  • Fixed to remove heartbeat trap (cpqHo2GenericTrap) delivery at OS boot when periodic test trap feature is disabled
  • Fixed memory leak partly caused by AMS running in the OS init resource group
  • Fixed reporting of the embedded SATA controller to resolve missing drives in the iLO Storage Tab display

WBEM Providers

  • Added support for Smart Array Controller model P408i-sb

Agentless Management Service

  • Added reporting of OS Logical Disk Volume Configuration and Utilization to iLO's Active Health System Log

Version:3.2.0 (21 Mar 2018)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

WBEM Providers

  • Fixed to report HPE Smart array P816i-a SR Gen10 controller Information on vSphere 6.0 and 6.5. For more information, see the customer advisory at http:// h20566.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-a00019315en_us.
  • Fixed to report HPE Dynamic Smart Array B140i Controller Information if nhpsa driver supported Smart Array Controller is also configured in that server on vSphere 6.5. For more information, see the customer advisory at http://h20566.www2.hpe.com/hpsc/doc/ public/display?docId=emr_na-a00016048en_us.
  • Fixed Memory leak issue in HPE Insight Management WBEM Provider on VMware vSphere 6.0 and 6.5. For more information, see the customer advisory at http:// h20566.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-a00019892en_us.
  • Fixed to report HealthState property for HPVC_SAStorageVolume and HPVC_SAStorageExtent to match SSACLI status.
  • Fixed number of HPVC_SAStorageVolume instances to match with SSACLI.

Agentless Management Service

  • Fix continuous PCIe Disk Temperature Failed (cpqSePCIeDiskTemperatureFailed) and PCIe Disk Wear Status Change (cpqSePCIeDiskWearStatusChange) traps when there are 3 or more NVMe drives in the system

Agentless Management Service

  • Added reporting of proper part number for HPE Dual 8GB MicroSD EM USB Device
  • Added support for HPE Smart Array P824i-p MR controller
  • Added support for reporting multiple IPV6 addresses configured for Ethernet ports
  • Added support for Periodic heartbeat trap (cpqHo2GenericTrap)
  • Added support for Host OS Graceful shutdown due to Critical Thermal/Fan Failure events in HPE Gen10 Servers

Version:3.1.5 (9 Nov 2017)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

HPE Insight Management WBEM Providers:

HPE Insight Management WBEM Providers does not report HPE Dynamic Smart Array B140i Controller Information if nhpsa driver supported Smart Array Controller is also configured in that server on vSphere 6.5

This issue is observed on vSphere 6.5 when the server is configured with an HPE Dynamic Smart Array B140i Controller supported by the hpdsa driver and smart array controller supported by the nhpsa driver. In this configuration, the HPE Insight Management WBEM Provider do not report the HPE Dynamic Smart Array B140i Controller instances information it only reports the Smart Array Controller instances information.

HPE Insight Management WBEM Providers does not support HPE Smart Array P816i-a SR Gen10 controller on vSphere 6.0 and 6.5

This issue is observed on both vSphere 6.0 and 6.5 OS, when the server is configured with HPE Smart Array P816i-a SR Gen10 controller. In this configuration, the HPE Insight Management WBEM Providers do not report any information of the HPE Smart Array P816i-a SR Gen10 controller.

HPE Insight Management WBEM Providers is not reporting the actual OperationalStatus of FC port and WBEM indications are also not generated

When FC Adapter “HP FlexFabric 10Gb 2-port 536FLB” is installed on a server and the FC cable is connected or disconnected from ports, HPE Insight Management WBEM Providers report wrong value for the OperationalStatus property in FC Provider classes and the WBEM indications are not generated. OperationalStatus reports the changed status only after WBEM Provider restarts.

Fixed memory leak. For more information, see the customer advisory at http://h20565.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-a00019892en_us.

HPE Agentless Management Service:

  • Fixed status for unconnected Fiber Channel ports that cause Fiber Channel Controller status to show as Degraded.
  • Fixed cpqIdeAtaDiskStatus which always shows SMART error and causing cpqIdeAtaDiskCondition as Degraded.

Added HPE Insight Management WBEM Provider support for new FCHBA.


Version:3.1.1 (28 Jul 2017)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Fixed Memory leak in HPE Insight Management WBEM Provider on VMware vSphere 6.5


Version:3.1.0 (12 Jul 2017)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

AMS fixes:

  • Fixed /tmp folder exhaustion with ahs.debug file when running over 128 CPU threads on the Host Server
  • Fixed AMS crash when multiple NICs of the same driver are installed

WBEM Provider features:

  • Gen10 and newer servers are Agentless, meaning the providers are limited to only the part of the Smart Array provider required to support Smart Array in VMware vCenter. Full providers continue to be supported on Gen9 and earlier servers.
  • Added support for smartpqi driver and Gen10 Smart Array controllers.
  • Added support to send Test Indication periodically to all the subscribers based on the time-interval value(days) configured from testevent utility.
  • Added Firmware update audit logging support to Smart Component Installer provider

AMS features:

  • Added new SMA (System Management Assistant) feature for Gen10 which allows SNMP traps generated by iLO Agentless Management and AMS to be delivered through the Host OS Management Port
  • Added support for new MIB OIDs cpqSasPhyDrvSsBoxModel, cpqSasPhyDrvSsBoxSerialNumber, cpqSasPhyDrvSsBoxFwRev, and cpqSasPhyDrvSsBoxVendor

The Agentless Management Service script to manually stop or restart AMS has changed from hp-ams.sh to ams.sh.


Version:2.6.2 (15 May 2017)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

  • There is an updated hpe-ilo driver included in this bundle. For more information, see the VMware Knowledge Base Article at http://kb.vmware.com/kb/2148123and the HPE Customer Advisory at http://h20565.www2.hpe.com/hpsc/doc/public/display?docId=c05378386.
  • HPE Insight Management WBEM Providers does not report HPE Dynamic Smart Array B140i Controller Information if an nhpsa driver supported HPE Smart Array Controller is also configured in the same server on vSphere 6.5 - This issue is observed on vSphere 6.5 when the server is configured with a combination of a HPE Dynamic Smart Array B140i Controller that supports hpdsa driver and a HPE Smart Array Controller that supports an nhpsa driver. The HPE Insight Management WBEM Providers does not report the HPE Dynamic Smart Array B140i Controller instances and only reports the HPE Smart Array Controller instances that supports the nhpsa driver.


Version:2.6.0 (18 Nov 2016)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Provider Features:

  • Added support for Native Interface in Ethernet Port Provider
  • Added support for Native interface in Smart Array Provider

AMS features:

  • Added support for new SNMP traps for HPE NVMe PCIe Solid State Drives

Type:Software - System Management
Version:3.6.0(5 Oct 2020)
Operating System(s):
VMware vSphere 6.5

Description

The HPE ESXi Offline Bundle for VMware ESXi 6.5 includes the latest HPE Common Information Model (CIM) Providers, HPE Integrated Lights-Out (iLO) driver, HPE Compaq ROM Utility (CRU) driver, the HPE Agentless Management Service (AMS), and Fibre Channel(FC) HBA access libraries.

Enhancements

Agentless Management Service

Added the option to enable/disable AHS Logical Disk Usage logging

Installation Instructions

To ensure the integrity of your download, HPE recommends verifying your results with this SHA-256 Checksum value:

55bcdc680d52ad56d9428249eb6a702ba873ec94848ad096ea5712020ed3e54desxi6.5uX-mgmt-bundle-3.6.0-9.zip

Reboot Requirement:
Reboot is required after installation for updates to take effect and hardware stability to be maintained.

Installation:

Installing Offline Bundles on an vSphere 6.5 Host Using vSphere CLI 6.5 esxcli Utility

You can use the esxcli utility in conjunction with offline bundles or with a depot. This topic describes
the procedure using offline bundles.

Prerequisites
Before you can update or patch an vSphere 6.5 host from the command line, you must have access to a machine on which you can run the VMware vSphere Command-Line Interface 6.5 (vSphere CLI). You can install the vSphere CLI on your Microsoft Windows or Linux system. For information about importing or installing the
vSphere CLI 6.5, see the VMware vSphere Command-Line Interface Installation and Reference Guide.

Procedure

  1. Power off any virtual machines that are running on the host and place the host into maintenance mode.
  2. Transfer the offline bundle onto the ESXi host local path, or extract it onto an online depot.
  3. Install the bundle on the ESXi host.
    • Install remotely from client, with offline bundle contents on a online depot:
      esxcli -s <server> -u root -p mypassword software vib install -d <depotURL/bundle-index.xml>
    • Install remotely from client, with offline bundle on ESXi host:
      esxcli -s <server> -u root -p mypassword software vib install -d <ESXi local path><bundle.zip>
    • Install from ESXi host, with offline bundle on ESXi host:
      esxcli software vib install -d <ESXi local path><bundle.zip>
  4. After the bundle is installed, reboot the ESXi host for the updates to take effect.
  5. (Optional) Verify that the vibs on the bundle are installed on your ESXi host.
    esxcli -s <server> -u root -p mypassword software vib list
  6. (Optional) Remove individual vibs. <vib name> can be identified by listing the vibs as shown in #5.
    esxcli -s <server> -u root -p mypassword software vib remove -n <vib name>

Installing Offline Bundles on an vSphere 6.5 Host Using VMware vCenter Update Manager

The offline bundle can also be installed from VMware vCenter Update Manager as a patch. For more information and detailed instructions, see the VMware vCenter Update Manager Administration Guide.

Release Notes

End User License Agreements:
HPE Software License Agreement v1
Eclipse License
Libcurl End User License Agreement
Net-SNMP License
SNIA License
zlib End User License Agreement
Hewlett-Packard End User License Agreement

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Notes:

The HPE CIM Providers use modified SNIA HBAAPI open source code and is covered by the SNIA License.
A document of the changes made and the modified source code are available at http://vibsdepot.hpe.com/hpq/SNIA/HBAAPI/

Supported Devices and Features:

VMware vSphere version support:

  • VMware vSphere 6.5 U2
  • VMware vSphere 6.5 U3

Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Agentless Management Service

  • Add support for distributed switch to resolve AMS issue of not reporting the Host IP address
  • Fix duplicate IP address reporting issue
  • Add fix to skip CPU and Memory Usage data collection when CPU and Memory Usage Logging is disabled
  • Disable Logical Disk Usage logging by default

Revision History

Version:3.6.0 (5 Oct 2020)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Agentless Management Service

  • Add support for distributed switch to resolve AMS issue of not reporting the Host IP address
  • Fix duplicate IP address reporting issue
  • Add fix to skip CPU and Memory Usage data collection when CPU and Memory Usage Logging is disabled
  • Disable Logical Disk Usage logging by default

Agentless Management Service

Added the option to enable/disable AHS Logical Disk Usage logging


Version:3.5.0 (17 Jan 2020)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

WBEM Providers

  • Fix incorrect CacheOperationalStatus data for Smart Array B140i Controller
  • Fix memory leak issues causing ESXi host to become unresponsive or crash

Agentless Management Service

  • Fix buffer overrun when acquiring vib summary from ESXi host database
  • Fix cpqSePciSlotBoardName for empty slots with no CPU
  • Fix cpqSePciSlotBoardName for FC Adapters with specific Device IDs
  • Disable multiple IPv6 support in Gen9 to fix Host discovery issues due to missing support in iLO
  • Fix AMS hang when total IPv6 address string sizes exceed 256 bytes

Version:3.4.5 (16 Sep 2019)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Agentless Management Service

  • Fixed issue with AMS filling up tmp and causing VUM updates to Fail (https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00073323en_us)
  • Fixed issue with read spikes seen in Gen9 hosts with HPE 3PAR only every 5 minutes

Agentless Management Service

  • Added support for HPE Ethernet 10Gb 2-port 524SFP+ Adapter and HPE Ethernet 10Gb 2-port 548SFP+ Adapter

Version:3.4.0 (2 Apr 2019)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

WBEM Providers

  • Fixed false Solid State Disk Wear alert reported by the SmartArray WBEM provider

Agentless Management Service

  • Fixed reporting of HPE QLogic NX2 driver components in the cpqHoSwVer MIB to resolve blank Installed driver versions displayed in SUM

Agentless Management Service

  • Added support for cpqiscsi MIB
  • Implement configurable CPU and Memory Usage periodic logging to the iLO AHS (Active Health System) Log

Version:3.3.6 (29 Nov 2018)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Agentless Management Service

  • Fixed reporting of HPE Software in the cpqHoSwVer MIB to resolve blank Active versions for installed drivers displayed in SUM.
  • Fixed AMS crash when processing a Link Down/Up Trap for a NIC port that has multiple IPV6 addresses.

Version:3.3.0 (27 Jun 2018)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

WBEM Providers

  • Fixed issue with Smart Array Provider reporting change of battery status frequently

Agentless Management Service

  • Fixed to remove heartbeat trap (cpqHo2GenericTrap) delivery at OS boot when periodic test trap feature is disabled
  • Fixed memory leak partly caused by AMS running in the OS init resource group
  • Fixed reporting of the embedded SATA controller to resolve missing drives in the iLO Storage Tab display

WBEM Providers

  • Added support for Smart Array Controller model P408i-sb

Agentless Management Service

  • Added reporting of OS Logical Disk Volume Configuration and Utilization to iLO's Active Health System Log

Version:3.2.0 (21 Mar 2018)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

WBEM Providers

  • Fixed to report HPE Smart array P816i-a SR Gen10 controller Information on vSphere 6.0 and 6.5. For more information, see the customer advisory at http:// h20566.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-a00019315en_us.
  • Fixed to report HPE Dynamic Smart Array B140i Controller Information if nhpsa driver supported Smart Array Controller is also configured in that server on vSphere 6.5. For more information, see the customer advisory at http://h20566.www2.hpe.com/hpsc/doc/ public/display?docId=emr_na-a00016048en_us.
  • Fixed Memory leak issue in HPE Insight Management WBEM Provider on VMware vSphere 6.0 and 6.5. For more information, see the customer advisory at http:// h20566.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-a00019892en_us.
  • Fixed to report HealthState property for HPVC_SAStorageVolume and HPVC_SAStorageExtent to match SSACLI status.
  • Fixed number of HPVC_SAStorageVolume instances to match with SSACLI.

Agentless Management Service

  • Fix continuous PCIe Disk Temperature Failed (cpqSePCIeDiskTemperatureFailed) and PCIe Disk Wear Status Change (cpqSePCIeDiskWearStatusChange) traps when there are 3 or more NVMe drives in the system

Agentless Management Service

  • Added reporting of proper part number for HPE Dual 8GB MicroSD EM USB Device
  • Added support for HPE Smart Array P824i-p MR controller
  • Added support for reporting multiple IPV6 addresses configured for Ethernet ports
  • Added support for Periodic heartbeat trap (cpqHo2GenericTrap)
  • Added support for Host OS Graceful shutdown due to Critical Thermal/Fan Failure events in HPE Gen10 Servers

Version:3.1.5 (9 Nov 2017)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

HPE Insight Management WBEM Providers:

HPE Insight Management WBEM Providers does not report HPE Dynamic Smart Array B140i Controller Information if nhpsa driver supported Smart Array Controller is also configured in that server on vSphere 6.5

This issue is observed on vSphere 6.5 when the server is configured with an HPE Dynamic Smart Array B140i Controller supported by the hpdsa driver and smart array controller supported by the nhpsa driver. In this configuration, the HPE Insight Management WBEM Provider do not report the HPE Dynamic Smart Array B140i Controller instances information it only reports the Smart Array Controller instances information.

HPE Insight Management WBEM Providers does not support HPE Smart Array P816i-a SR Gen10 controller on vSphere 6.0 and 6.5

This issue is observed on both vSphere 6.0 and 6.5 OS, when the server is configured with HPE Smart Array P816i-a SR Gen10 controller. In this configuration, the HPE Insight Management WBEM Providers do not report any information of the HPE Smart Array P816i-a SR Gen10 controller.

HPE Insight Management WBEM Providers is not reporting the actual OperationalStatus of FC port and WBEM indications are also not generated

When FC Adapter “HP FlexFabric 10Gb 2-port 536FLB” is installed on a server and the FC cable is connected or disconnected from ports, HPE Insight Management WBEM Providers report wrong value for the OperationalStatus property in FC Provider classes and the WBEM indications are not generated. OperationalStatus reports the changed status only after WBEM Provider restarts.

Fixed memory leak. For more information, see the customer advisory at http://h20565.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-a00019892en_us.

HPE Agentless Management Service:

  • Fixed status for unconnected Fiber Channel ports that cause Fiber Channel Controller status to show as Degraded.
  • Fixed cpqIdeAtaDiskStatus which always shows SMART error and causing cpqIdeAtaDiskCondition as Degraded.

Added HPE Insight Management WBEM Provider support for new FCHBA.


Version:3.1.1 (28 Jul 2017)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Fixed Memory leak in HPE Insight Management WBEM Provider on VMware vSphere 6.5


Version:3.1.0 (12 Jul 2017)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

AMS fixes:

  • Fixed /tmp folder exhaustion with ahs.debug file when running over 128 CPU threads on the Host Server
  • Fixed AMS crash when multiple NICs of the same driver are installed

WBEM Provider features:

  • Gen10 and newer servers are Agentless, meaning the providers are limited to only the part of the Smart Array provider required to support Smart Array in VMware vCenter. Full providers continue to be supported on Gen9 and earlier servers.
  • Added support for smartpqi driver and Gen10 Smart Array controllers.
  • Added support to send Test Indication periodically to all the subscribers based on the time-interval value(days) configured from testevent utility.
  • Added Firmware update audit logging support to Smart Component Installer provider

AMS features:

  • Added new SMA (System Management Assistant) feature for Gen10 which allows SNMP traps generated by iLO Agentless Management and AMS to be delivered through the Host OS Management Port
  • Added support for new MIB OIDs cpqSasPhyDrvSsBoxModel, cpqSasPhyDrvSsBoxSerialNumber, cpqSasPhyDrvSsBoxFwRev, and cpqSasPhyDrvSsBoxVendor

The Agentless Management Service script to manually stop or restart AMS has changed from hp-ams.sh to ams.sh.


Version:2.6.2 (15 May 2017)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

  • There is an updated hpe-ilo driver included in this bundle. For more information, see the VMware Knowledge Base Article at http://kb.vmware.com/kb/2148123and the HPE Customer Advisory at http://h20565.www2.hpe.com/hpsc/doc/public/display?docId=c05378386.
  • HPE Insight Management WBEM Providers does not report HPE Dynamic Smart Array B140i Controller Information if an nhpsa driver supported HPE Smart Array Controller is also configured in the same server on vSphere 6.5 - This issue is observed on vSphere 6.5 when the server is configured with a combination of a HPE Dynamic Smart Array B140i Controller that supports hpdsa driver and a HPE Smart Array Controller that supports an nhpsa driver. The HPE Insight Management WBEM Providers does not report the HPE Dynamic Smart Array B140i Controller instances and only reports the HPE Smart Array Controller instances that supports the nhpsa driver.


Version:2.6.0 (18 Nov 2016)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Provider Features:

  • Added support for Native Interface in Ethernet Port Provider
  • Added support for Native interface in Smart Array Provider

AMS features:

  • Added support for new SNMP traps for HPE NVMe PCIe Solid State Drives

Mib

3par Mib Downloads Download